SCHMIDT® Flow Sensor SS 23.400 ATEX

Thermal flow sensor for uni- or bidirectional measurement of flow rate of air and gases with simultaneous detection of the flow direction in an explosive atmosphere (Zone 2).

 

  • Thermopile head (very fast response time)
  • Flow velocity and switching signals
  • Probe length 130 … 300 mm
  • Measuring ranges 0 … 1 m/s to 0 … 20 m/s
  • Bidirectional measurement (optional)
  • Detection of flow direction (optional)
  • Sensor programming (optional)
  • Cleanroom sensor
  • Extremely compact (electronics is integrated in sensor tube)
  • Sensor element protected against mechanical stress
  • Linear analog output for measured flow velocity
  • Two switching outputs to signal flow direction and threshold
  • ATEX gases, zone 2: II 3G Ex nA IIC T4 Gc

 

  • Laminar flow monitoring in cleanrooms
  • Monitoring of overflow
  • Cooling air monitoring
  • Flow measurement in test benches
  • Mass and volume flow measurement

 

SCHMIDT Technology – Simply a question of better measurement

Specifications

Technical data
Measuring quantityStandard flow velocity wN based on standard conditions 1)
Measured mediumClean air or nitrogen, additional gases on request
Measuring range wN(±)0 … 1 / 2.5 / 5 / 10 / 20 m/s (uni- or bidirectional)
Lower detection limit wN(±)0.05 m/s
Measuring accuracy
Standard wN±(3 % of measured value + [2 % of fmr; min. 0.05 m/s]) 2)
High precision (optional) wN±(1 % of measured value + [2 % of fmr; min. 0.04 m/s]) 2)
Response time (t90) wN1 s (configurable: 0.01 … 10 s)
Operating temperature
Sensor0 … +60 °C
Storage temperature-20 … +85 °C
Material
Sensor headStainless steel 1.4404
Sensor tubeStainless steel 1.4404
Plug-in connector, nut screwStainless steel 1.4404
General data
HumidityMeasuring mode: Non-condensing (< 95 % RH)
Operating pressure (max.)Atmospheric (700 … 1,300 hPa)
Supply voltage12 … 26.4 V DC
Current consumptionTyp. < 35 mA (max. 150 mA; including signal current of switching outputs)
Analog output wN0 … 10 V (RL > 10 kΩ; CL ≤ 10 nF; short-circuit protected)
4 … 20 mA (RL < 300 Ω; CL ≤ 100 nF)
Switching outputs2 x open collector (at GND), current-limited and short-circuit protected, configurable
-Channel 1 (OC1): Flow direction or threshold value
- Channel 2 (OC2): Threshold value
- External switching voltage / current: Max. 26.4 V DC / 55 mA (typ. 50 mA)
- Hysteresis: 5 % of threshold value (min. ±0.05 m/s)
Electrical connectionPlug-in-connector M9, male, 7-pin (shielded), screwed
Maximum cable lengthVoltage interface: 15 m;
Current interface: 100 m
Mounting positionArbitrary
Protection typeSensor probe: IP66
Plug-in connection: IP67 (with correct attached cable)
Protection classIII / PELV (EN 50178)
ATEX declarationGas (zone 2): II 3G Ex nA IIC T4 Gc
Probe length130/200/300 mm
WeightApprox. 60 g max. (300 mm Sensor length)

1) Standard conditions: TN = 20 °C and pN = 1,013.25 hPa

2) Related to adjustment reference; "fmr" = final measuring range

Subject to technical changes

Order information

 DescriptionArticle-Number
Basic sensorSCHMIDT® Flow Sensor SS 23.400 ATEX, thermopile head, with ATEX* category 3G, zone 2)513 970 -XYDZR4P
 Options
Mechanical typeSensor length 130 mm (only with 0 … 10 V output available) 1      
Sensor length 200 mm 2      
Sensor length 300 mm 3      
Measuring rangeMeasuring range 0 … 1 m/s  1     
Measuring range 0 … 2.5 m/s  2     
Measuring range 0 … 5 m/s  3     
Measuring range 0 … 10 m/s  4     
Measuring range 0 … 20 m/s  5     
Measurement direction, adjustment accuracy and calibrationUnidirectional – standard adjustment   1    
Unidirectional – standard adjustment with factory calibration certificate   6    
Bidirectional – standard adjustment   2    
Bidirectional – standard adjustment with factory calibration certificate   7    
Unidirectional – high precision adjustment incl. factory calibration certificate   3    
Bidirectional – high precision adjustment incl. factory calibration certificate   4    
Unidirectional LF - optimized for Laminar Flow application, high precision, with factory calibration certificate (only for measuring range 1 m/s)   5    
Output signals0 … 10 V    1   
4 … 20 mA (not for length 130 mm)    5   
Direction representationBidirectional: switching output OC 1     1  
Bidirectional: halved analog signal (0 m/s = 12 mA / 5 V)     2  
Unidirectional     3  
Sensor programmingFactory setting       S
Customer-specific programming       K

* Use of the sensor in the ATEX zone only in conjunction with the original connecting cable 535 279

Accessories

Connection technology

DescriptionArticle-Number
Connection cable with coupler socket, 5 m length, open cable ends, material PUR535 279
Power supply unit: output 24 V / 1A DC, supply voltage 115/230 V AC (strip terminal)535 282

Mounting and fixing technology

DescriptionArticle-Number
Wall mounting flange, stainless steel 1.4571520 181
Compression fitting stainless steel, G½, atmospheric pressure532 160
Wall mounting bracket, aluminium, anodized503 895
Mounting flange, stainless steel 1.4404551 740
Assembly kit for pipe assembly suitable for MD 10.010/10.015 including pipe clamps and collar for adjustment to pipe diameter531 394

Measured value display

DescriptionArticle-Number
LED display MD 10.010 in wall housing to show volume flow and flow velocity, 85 … 250 V AC and sensor power supply527 320
LED display MD 10.010, similar to 527 320 but with 24 V DC voltage supply528 240
LED display MD 10.015, similar to 527 320 but with an additional sum function and a second measuring input527 330
LED display MD 10.015, similar to 527 330 but with 24 V DC voltage supply528 250

Miscellaneous

DescriptionArticle-Number
Calibrator MK 40.415 - Set (8 / 12 / 16 mA)546 741 - 4

Downloads