SCHMIDT® Duplex-Laminar-Flow Sensor SS 20.415 Twin

Doubled validation of laminar flow

(registered design)

 

Thermal duplex flow sensor for redundant validation of laminar flow applications at one measuring point.

 

  • Redundant validation of laminar flow applications
  • Two independent, full-fledged flow sensors in one unit
  • Easy installation at one measuring point
  • No mutual influence of measurements
  • Confined space becomes a minor matter
  • ‚Plug and Play’ combined with quick assembly
  • Precise measurement of low flow velocity [wN]
  • Straight and angled design for wall and ceiling mounting
  • Probe length straight version: 300 mm
  • Probe length angled version: 150 / 270 mm x 300 mm
  • Measuring ranges 0 … 1 m/s to 0 … 2.5 m/s
  • Cleanroom sensor
  • Extremely compact (electronics are integrated in tubes)
  • Sensor element protected against mechanical stress
  • Linear analog output for measured value output
  • Serial number of sensor is visible when installed
  • Special version for laminar-flow monitoring in cleanrooms with quick-mounting system for simple installation beneath a ceiling systems or at walls

 

  • Laminar flow monitoring in cleanrooms
  • Flow monitoring in pharmaceutical production, semiconductor manufacturing, food production, LCD manufacturing and optical industry
  • Integration into insulators, FFUs and flow boxes

 

 

SCHMIDT Technology – Simply a question of better measurement

Specifications

Technical data
Measuring quantityStandard flow velocity wN based on standard conditions 1)
Measured mediumClean air or nitrogen, additional gases on request
Measuring range wN0 … 1 / 2.5 m/s
Max. display range wN+10 % above measuring range
Lower detection limit wN0.05 m/s
Measuring accuracy
Standard wN±(3 % of measured value + 0.05 m/s) 2)
High precision (optional) wN±(1 % of measured value + 0.04 m/s) 2)
Response time (t90) wN5 s
Operating temperature
Sensor0 … +60 °C
Storage temperature-20 … +85 °C
Material
Sensor headStainless steel 1.4404
Sensor tubeStainless steel 1.4404
Plug connector, nut srewStainless steel 1.4404
Light ringPC
General data
HumidityMeasuring mode: Non-condensing (< 95 % RH)
Operating pressure (max.)Atmospheric (700 … 1,300 hPa)
Supply voltage24 V DC ± 10 %
Current consumptionTyp. 32 mA / max. 45 mA (including all signal output currents)
Analog outputs wN,A & wN,B0 … 10 V (RL ≥ 10 kΩ; short-circuit protected)
4 … 20 mA (RL ≤ 300 Ω>br> CL ≤ 10 nF
Error signalOnly with current interface: 2 mA (according to NAMUR NE43)
Electrical connectionPlug-in-connector M9, male, 7-pin (shielded), screwed
Maximum cable lengthVoltage interface: 10 m
Current interface: 100 m
Mounting positionStraight: ±3° relative to flow direction
Angled: Vertical downdraft flow (per design)
Protection typeSensor: IP65; electrical connector: IP67 (with correctly attached cable)
Protection classIII (SELV) or PELV (EN 50178)
Sensor lengthAngled: 150/270 mm (vertical) x 300 mm (horizontal)
Straight: 300 mm
WeightApprox. 250 g (angled design with 270 mm x 300 mm)

1) Standard conditions: TN = 20 °C and pN = 1,013.25 hPa

2) Related to adjustment reference; "fmr" = final measuring range

Subject to technical changes.

Order information

 DescriptionArticle-Number
Basic sensorSCHMIDT® Duplex-Laminar-Flow Sensor SS 20.415 Twin with thermopile heads; Basic version: wN1 and wN2566 950 -ABCDEFG
Options
TypeStandard 1      
Mechanical typeSensor length 150 mm x 300 mm (angled)  1     
Sensor length 270 mm x 300 mm (angled)  2     
Sensor length 300 mm (straight)  3     
Mechanical fixingThreaded bushing M25 with counternut (type 1)   1    
Threaded bushing M25 with thread adapter M25 x 1.5 to PG21 (type 2)   2    
Threaded bushing M25 with shank nut (type 3)   3    
Welding bushing (type 4)   4    
Flange bushing (type 5)   5    
Without fixation material   6    
Measuring range0 … 1 m/s    1   
0 … 2.5 m/s    2   
Output signals0 … 10 V     1  
4 … 20 mA     2  
Adjustment accuracy and calibrationStandard adjustment without certificate      1 
Standard adjustment with certificate      2 
High precision adjustment with factory calibration certificate      3 
Sensor programmingFactory setting       1

Accessoroes

Connection technology

DescriptionArticle-Number
Coupler socket, 7-pin, with soldering sleeves for cable-Ø 0.14 mm²535 278
Connection cable with coupler socket, 7-pin, 5 m length, open cable ends, material PUR535 279
Connection cable with coupler socket, 7-pin, length selectable (2 … 100 m; 1 m steps), open cable ends505 911 - 4
Connection cable with angled socket, 7-pin, 10 m length, open cable ends, material PUR535 281
Power supply unit: output 24 V / 1A DC, supply voltage 115/230 V AC (strip terminal)535 282

Mounting and fixing technology

DescriptionArticle-Number
Assembly kit for pipe assembly suitable for MD 10.010/10.015, including pipe clamps and collar for adjustment for pipe diameter531 394

Measured value display

DescriptionArticle-Number
LED display MD 10.010 in wall housing to show volume flow and flow velocity, 85 … 250 V AC and sensor power supply527 320
LED display MD 10.010, similar to 527 320 but with 24 V DC voltage supply528 240
LED display MD 10.015, similar to 527 320 but with an additional sum function and a second measuring input527 330
LED display MD 10.015, similar to 527 330 but with 24 V DC voltage supply528 250

Miscellaneous

DescriptionArticle-Number
Calibrator MK 40.415 - Set (8 / 12 / 16 mA)546 741 - 4

Downloads

Back to Top