Specifications
Technical data | |
---|---|
Measuring quantity | Standard flow velocity wN based on standard conditions 1) Temperature of medium TM |
Measured medium | Air or nitrogen, other gases upon request |
Measuring range wN | 0 … 40 / 60 / 90 m/s |
Lower detection limit wN | 0.2 m/s |
Measuring range TM | -20 … + 85 °C |
Measuring accuracy | |
Standard wN | ±(5 % of measured value + 0.4 % of fmr) 2) |
High precision (optional) wN | ±(3 % of measured value + 0.4 % of fmr) 2) |
Response time (t90) wN | 3 s (jump from 0 to 5 m/s) |
Temperature gradient wN | ≤ 8 K/min (at wN = 5 m/s in air) |
TM (wN > 2 m/s) | ±1 K (0 … 40 °C); ±2 K (in remaining measuring range) |
Operating temperature | |
Sensor probe | -20 … +85 °C |
Electronics | 0 … +70 °C |
Material | |
Enclosure | PBT (glass-fibre reinforced) |
Sensor tube | Stainless steel 1.4571 |
Sensor head | Platinum element (glass passivated); PPO/PA |
Compression fitting | Brass (G½) / stainless steel 1.4305 (R½) (order options) |
Sensor cable | PVC |
General data | |
Humidity | Measuring mode: Non-condensing (< 95 % RH) |
Operating pressure (max.) | 10 bar (overpressure) |
Display | LED green: Operating state LED red (flashing): Sensor defective |
Supply voltage | 24 V DC ± 10 % |
Current consumption | Typ. < 40 mA, max. 60 mA |
Analog outputs (wN and TM) | 4 … 20 mA (RL ≤ 300 Ω, CL ≤ 10 nF), short circuit protected |
Electrical connection | Non-detachable cable , 4 x 0,14 mm2, length 5 m, with ferrules |
Maximum cable length | 100 m |
Mounting position | Arbitrary (except in case of a downward flow and < 2 m/s at the same time) |
Mounting tolerance | ±3° relative to flow direction (unidirectional) |
Protection type | Sensor probe: IP66; enclosure: IP54 |
Protection class | III (SELV) or PELV (EN 50178) |
Probe length L | 200/350 mm |
Weight | 250 g (max.; L = 350 mm) |
1) Standard conditions: TN = 20 °C and pN = 1,013.25 hPa
2) Related to adjustment reference; "fmr" = final measuring range
Subject to technical changes